EMA Linear Actuator

Tel: +44 (0) 1358 285100 email: [email protected]

web: www.powerjacks.com

12

7.

Electrical Installation

7.1

Limit Switch

– Electro-Mechanical Type

Item

Description

Housing

Metal, compact housing, totally
enclosed and sealed.

Pre-Cabled

2m PVC cable 5x0.75mm

2

(other

cable

lengths

available

on

request).

Switch type

Single-pole, 1 change-over, snap
action.

Switch Actuation

End of plunger (metal).

Max actuation speed

0.5 m/s

Mechanical durability

10 million operating cycles.

Ambient temperature
Operation
Storage


-25°C  +70°C
-40°C  +70°C

Product conformity

IEC947-5-1

Enclosure

IP67

Operating characteristics AC-15; B300 (Ue=240V, Ie=1.5A)

DC-13; R300 (Ue=250V, Ie=0.1A)

Insulation voltage

Ui=300V

7.2

Mounting the drive motor


The electrical installations and the checking of the direction of rotation
may only be carried out be a licensed electrician.





Connect the motor in compliance with the electro-technical regulation




Before mounting the motor, check the direction of rotation / linear travel of the EMA
actuator and the operation of the limit switches (if fitted). In order to do this:

1. Place the motor at the mounting position near the gearbox input.
2. Switch on the motor and check the direction of rotation.
3. Check the direction of rotation / linear travel by manually turning the gearbox input

shaft. Change the direction of the motor rotation if necessary by changing motor
connections.

4. Where necessary, attach coupling halves to motor shaft.
5. Mount motor onto gearbox input flange using screws provided.