Operation – Power Jacks C-Series User Manual

Page 20

Advertising
background image

20

www.powerjacks.com

Operation

5

5.2.28

Connecting Screw Jacks in Series

The number of screw jacks that can be connected in series is limited by input torque

requirements on the first worm shaft in the line. For the C-Series the torque on the worm shaft

of the first screw jack should not exceed 300% of its rated full load torque (this does not include

the 200kN screw jacks which are rated at 200%).

5.2.29

Efficiency of a Multiple Screw Jack System

In addition to individual device efficiencies, the efficiency of the screw jack arrangement must

be taken into consideration. The arrangement efficiency allows for misalignment due to slight

deformation of the structure under load, for the losses in couplings, bearings, and for a normal

amount of misalignment in positioning the screw jacks and gearboxes. For efficiency values

consult Power Jacks product literature or engineers.

5.2.30

Screw Jack Fitted with 3rd Party Accessories

If your screw jack is fitted with a device not manufactured by Power Jacks then please consult

the provided manual for this device.

Advertising