Red Lion PAX2S User Manual

Description, Safety summary, Dimensions in inches (mm)

Advertising
background image

1

3.80 (96.52)

(49.53)

(2.54)

(44.45)

3.60 (91.44)

4.14 (105)

1.95

0.10

1.75

1

3

2

4

z

LOAD CELL, PRESSURE AND TORQUE BRIDGE INPUTS

z

UNIVERSAL AC/DC POWER SUPPLY

z

SELECTABLE 5 VDC OR 10 VDC BRIDGE EXCITATION

z

PROGRAMMABLE AUTO-ZERO TRACKING

z

6 / 9 DIGIT DUAL LINE/TRI-COLOR DISPLAY WITH 0.71" & 0.35"

DIGITS

z

PROGRAMMABLE UNITS DISPLAY

z

VARIABLE CONTRAST AND INTENSITY DISPLAY

z

UP TO 160 SAMPLES PER SECOND CONVERSION RATE

z

BUILT-IN USB PROGRAMMING PORT ENABLING UNIT

CONFIGURATION WITH CRIMSON PROGRAMMING SOFTWARE

z

NEMA 4X/IP65 SEALED FRONT BEZEL

DESCRIPTION

The PAX2S Strain Gage Panel Meter offers many features and performance

capabilities to suit a wide range of industrial applications. The PAX2S has a

strain gage input to handle various types of bridge configurations including load

cell, pressure and torque sensors. The optional plug-in output cards allow the

opportunity to configure the meter for present applications, while providing easy

upgrades for future needs.

Highlighting the PAX2S is a dual line, display with a large 0.71", tri-color 6

digit top display line and a 0.35", 9 digit green bottom display line. The meter

also offers programmable units display, providing capability to tag the display

with units of measure. Display color change capability provides machine

operators a visual display of changing conditions, even when the operator is not

close enough to read the actual display value. In addition, a universal power

supply provides the ultimate in flexibility for both AC and DC power.

The meter provides a MAX and MIN reading memory with programmable

capture time. The capture time is used to prevent detection of false max or min

readings which may occur during start-up or unusual process events. The signal

totalizer (integrator) can be used to compute a time-input product. This can be

used to provide a readout of totalized weight or calculate service intervals of

motors, pumps, etc.

The meter has up to four setpoint outputs, implemented on plug-in option

cards. The plug-in cards provide dual FORM-C relays, quad FORM-A, or either

quad sinking or quad sourcing open collector logic outputs. The setpoint alarms

can be configured to suit a variety of control and alarm requirements.

The PAX2 can be programmed to utilize Modbus protocol. With Modbus, the

user has access to all configuration parameters. Readout values and setpoint

alarm values can be controlled through the bus. Additionally, the meter has a

feature that allows a remote computer to directly control the outputs of the

meter. Communication and bus capabilities are also available as option cards.

These include RS232, RS485, DeviceNet, and Profibus-DP.

The PAX2 includes a built-in USB programming port. With a Windows

®

based program, made available by Red Lion Controls, configuration data can be

downloaded to the PAX2 without the need of any additional option cards.

A linear DC output signal is available as an optional plug-in card. The card

provides either 20 mA or 10 V signals. The output can be scaled independent of

the input range and can track either the input, totalizer, max or min readings, or

any setpoint value.

After the meter has been initially configured, the parameter programming

may be locked out from further modification in its entirety, or allowing selected

values accessible for quick entry.

The meter has been specifically designed for harsh industrial environments.

With NEMA 4X/IP65 sealed bezel and extensive testing of noise effects with

regard to CE requirements, the meter provides a tough reliable application

solution.

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in this

literature or on equipment must be observed to ensure personal safety and to

prevent damage to either the instrument or equipment connected to it. If

equipment is used in a manner not specified by the manufacturer, the protection

provided by the equipment may be impaired. Do not use this unit to directly

command motors, valves, or other actuators not equipped with safeguards. To do

so can be potentially harmful to persons or equipment in the event of a fault to

the unit.

MODEL PAX2S – 1/8 DIN STRAIN GAGE INPUT PANEL METER

DIMENSIONS In inches (mm)

Note: Recommended minimum clearance (behind the panel) for

mounting clip installation is 2.1" (53.4) H x 5.5" (140) W.

PANEL CUT-OUT

Bulletin No. PAX2S-B
Drawing No. LP0885
Released 04/13

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net