LINE 2 PARAMETERS (LINE 2)

This section details programming for the Line 2 (Bottom Line) Display. The Input, Gross, Tare, Total, Max, Min, Setpoint, Band/Deviation values and Parameter

List A/B status can be shown on the Line 2 display. The display loops described below are used to view, reset and modify the selected display values, based on the

Line 2 Value Access setting programmed for each available value.

Main Display Loop

In the Main display loop, the selected values can be consecutively read on Line 2 by pressing the

D key. A left justified 2, 3 or 4-character mnemonic indicates which

Line 2 value is currently shown. When in the Main display loop, the Function keys ! and @ perform the User functions programmed in the User Input program

section.

Parameter Display Loop and Hidden Parameter Loop

These display loops provide quick access to selected parameters that can be viewed and modified on Line 2 without having to enter Full Programming Mode. These

values include Parameter List A/B selection, Setpoints and Display Settings (color, intensity and contrast). To utilize the Parameter or Hidden Parameter display loops,

a security code (1-250) must be programmed. (See Programming Security Code at the end of this section.)

The Parameter display loop is accessed by pressing the

P key. The selected Parameter display loop values can be viewed and/or changed per the Line 2 Value Access

setting programmed for each available value. The Hidden Parameter loop follows the Parameter display loop, and can only be accessed when the correct security code

is entered at the Code prompt.

dISPLY

LINE 2

ACCESS

NO

Ln2

Line 2

Value Access

FUNCt

NO

Ln2

Line 2 Function

Access

ScroLL

NO

Ln2

Line 2 Scroll

Enable/Time

UNItS

FACt

Ln2

Line 2 Units

Mnemonics

COdE

0

dSP

Programming

Security Code

Pro

dISPLY

Pro

NO

F1

F2

P

D

LINE 2 PARAMETER VALUE ACCESS

DISPLAY

DESCRIPTION

NOT

VIEWED

MAIN DISPLAY LOOP

(D KEY)

PARAMETER DISPLAY

LOOP (P KEY)

HIDDEN

LOOP

LOC

d-rEAd

d-rSt

d-Entr

P-rEAd

P-Entr

HidE

INPUt

Input

X

X

X

GrOSS

Gross (absolute)

X

X

tArE

Tare Value

X

X

X

tOtAL

Total

X

X

X

Hi

Max Value

X

X

X

Lo

Min Value

X

X

X

LISt

Parameter List A/B

X

X

X

X

X

X

Snx

Setpoint Value (S1-S4) *

X

X

X

X

X

X

bn-dn

Band/Deviation

X

X

X

X

X

X

Color

Line 1 Display Color

X

X

X

X

d-LEU

Display Intensity Level

X

X

X

X

d-Cont

Display Contrast Level

X

X

X

X

* Indicates multiple value entries.

LINE 2 VALUE ACCESS

NO YES

Select YES to program the Value Access setting for each available Line 2

parameter. Line 2 values can be made accessible in either the Main (

D key),

Parameter (

P key) or Hidden (P key following code entry) display loops. When

the List parameter is configured for an Entr setting, a List assignment sub-

menu will follow. Refer to Input module, User sub-menu section for a

description of the function.

Each parameter must be configured for one of the following settings. Not all

settings are available for each parameter, as shown in the Parameter Value

Access table.

SELECTION

DESCRIPTION

LOC

Not viewed on Line 2 Display (Factory Default Setting)

d-rEAd

View in Main display loop. Cannot change or reset.

d-rSt

View and reset in Main display loop.

d-Entr

View and change in Main display loop

P-rEAd

View in Parameter display loop. Cannot change or reset.

P-Entr

View and change in Parameter display loop

HidE

View and change in Hidden Parameter display loop

LINE 2 FUNCTIONS ACCESS

NO YES

Select YES to display the following list of functions that can be made

available at the end of the Parameter (P-Entr) or Hidden (HidE) display loops.

Each Line 2 Function can be programmed for LOC, P-Entr, or HidE.

The more critical and frequently used functions should be first assigned to the

User Inputs and User Function keys, however if more functions are needed than

what can be obtained with user inputs and function keys, these will provide a

means to provide that access. Refer to Input module, User sub-menu section for

a description of the function.

SELECTION

DESCRIPTION

rEL

Zero (tare) display

r-tArE

Reset Display Tare (offset) value

bAt

Store batch reading in Totalizer

r-tot

Reset Totalizer

r-HI

Reset Maximum value

r-LO

Reset Minimum value

r-HL

Reset Max and Min values

r-1

Reset Setpoint output 1

ACCESS

NO

Ln2

FUNCt

NO

Ln2