Altra Furniture Black Mezza L Desk User Manual

Page 7

Advertising
background image


BV Lab Number:

(6207)011-0396

Technician Name:

EH


Page 2 of 2

OD-9000-US

Packaged Product Transit Testing

Evaluation

Citation/Method

No.

Samples

Criteria

Results

Rating

Method 1A (150 lbs. or Less)

ISTA Procedure

1A

1

No Major Defects After 14,200 Vibratory Impacts

M

PASS

Method 1B (Over 150 lbs.)

ISTA Procedure

1B

1

No Major Defects After 11,800 Vibratory Impacts

NA

-

Impact:

Method 1A (150 lbs. or Less)
(For all samples, but not for CD
case)

ISTA Procedure

1A

1

No Major Damage After 10 Drops From A Specific Height In
A Specific Sequence As Described In ISTA Procedure 1A.
Test drop height varies with weight of packaged product.

M PASS

For CD case only

OD method

1

No Major Damage After 2 Drops From a 8” Height In Front &
Bottom.

NA -

For Laser Toner Cartridges Only

OD Method

1

Open the package after the drop test and inspect for toner
leakage, any evidence of leakage shall result in a FAIL rating.

NA -

Method 1B (Over 150 lbs.)

ISTA Procedure

1B

1

No Major Damage After 6 Drops From A 6” Height In A
Specific Sequence As Described In ISTA Procedure 1B.

NA -

WHEN APPLICABLE

* Impact Alternative For Skid-
Bottom Packages Or Those
Weighing 500 lbs. Or More

ASTM D1083

1

No Major Damage After Impacting The 4 Vertical Faces And
Completing two 8" Flat Rotational Drops To The Bottom
Surface

NA -

* Impact - Bridge (when L is 3x W
or D)

ASTM D5265

1

No Major Defects After Impact. Impactor height is to be
adjusted to achieve 2.4 m/sec (96.26”/sec)

NA -

* Impact – Rupture (for bags and
cylindrical containers)

ASTM D5276

1

No Major Defects After Drop Onto Rupture Hazard Which Is
a 4 x 4 in (102 x 102 mm) timber, of oak or other wood of
equivalent hardness, approx 4 ft (1.2 m) long - per standard.

NA -


Key:
M

Meets

NM

Does Not Meet

NA

Not Applicable

NT

Not Tested

*

Additional Charge For This Test

**

Mandatory Requirement

No. Of Samples Required For Complete Testing:

1

Client Approval:

No. Of (Fully Packed) Cartons For Transit Testing:

1

Creation Date:

July 9, 2003

No. Of Working Days For Complete Testing:

7

Last Revision Date:

August 3, 2006

Advertising