Atlas Guardian Pro MLGC240W User Manual

Guardian, Operation, 240 s

Advertising
background image

Mode:

On-Time:

Works:

Day

Night

Test

5 Seconds

x

x

Auto

1, 5, 20 min.

x

Manual

Until Dawn*

x

Accent

3, 6 Hr, to Dawn

x

OPERATION

* resets to Auto Mode at dawn.

MANUAL MODE

ON-TIME

20 5 1 TEST

... back on.

AUTO

1 Second OFF

then...

Move ON-TIME Switch to 1,

5, or 20 minutes

Mode Switching Summary

Flip light switch off

for one second then

back on*

MANUAL MODE

AUTO

TEST

Requirements

• The Light Control requires 120-volts AC.
• If you want to use Manual Mode, the control must be

wired through a switch.

Some codes require installation by a qualified

electrician.

• This product is intended for use with the enclosed

gasket and with a junction box marked for use in wet
locations.

Light Control

Sensor

Cover

Plate

Lamp Holders

2 Wire

Connectors

6 Screws

(3 sizes included)

Gasket

Features

• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Dual Light Level
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).

* If you get confused while switching modes, turn the

power off for one minute, then back on. After the
calibration time the control will be in the AUTO mode.

Note: When first turned on wait about 1

1

/

2

minutes for

the circuitry to calibrate.

Mounting Bolt

Mounting Strap

Plastic Hanger

Rubber Plug

Models MLGC240B

MLGC240W

GUARDIAN

PRO

240 S

ERIES

240-028-A

© 2003 Atlas Lighting Products, Inc.

598-1094-01

This package includes:

Put the ON-TIME switch in the 1, 5, or
20 minute position.

Manual mode only works at night
because daylight returns the sensor
to AUTO.

Flip the light switch off for one sec-
ond then back on to toggle between
AUTO and MANUAL MODE.

Manual mode works only with the
ON-TIME switch in the 1, 5, or 20
position.

2 Shells

TEST

TEST 1 5 20

ON-TIME

Off 3 6 Dusk to Dawn

DUAL LIGHT LEVEL

Put ON-TIME switch on the sensor bottom to TEST
and the Dual Light Level switch OFF.

Dual Light Level Control

Light comes on half bright for selected time after dusk
(Off, 3 hr., 6 hr., until dawn). If motion is sensed, the
light turns on full bright for the ON-TIME (1, 5, or 20
minutes) then returns to dim mode.