7

Installation & Programming Manual

Chapter 3: Set-Up & Programming

Getting Started

Before the 1746L PLC LDT Interface Module can communicate with the A-B SLC 500

processor, the system must be configured to include the 1746L PLC LDT Interface Module. This

is done through either the APS Software or the hand-held controller. When defining the system,

the program will prompt for a SPIOGA ID code. The ID code for the 1746L PLC LDT Interface

Module is: 3535. This tells the processor that the 1746L uses 8 input words and 8 output words.

Output Image Table

Because there are more than 8 parameters to program, the 1746L Interface Module uses a

command based programming sequence to enter parameters into the system. The first word of

the output image table is the command bit register. This bit register contains a programming bit

used to initiate the programming sequence. The second word is the command word and the other

5 words are used for the command parameters as shown in the table below:

Command Bit Register

The Command Bit Register has been defined below:

Programming Bit

The software monitors the programming bit for a 0 to 1 transition. When this is detected, it reads

the command register and processes the data based on the command specified. If the command

data and parameter data are valid, the acknowledge bit is set in the input image table bit register.

If the data is invalid, the error bit will be set in the input image table bit register. These bits are

cleared when the programming bit is set back to zero.

Chapter 3: Setup & Programming

Output Image Table

Description

Word 0

Command Bit Register

Bits 15

Programming Bit

Bits 14 - 8

Reserved

Bits 7

Data Format Bit

Bits 6

Velocity Bit

Bits 5 - 1

Reserved

Bit 0

Inch/mm

Word 1

Command Register

Word 2

Parameter 1

Word 3

Parameter 2

Word 4

Parameter 3

Word 5

Parameter 4

Word 6

Parameter 5

Word 7

Parameter 6

Bit 15

14

13

12

11

10

9

8

PROG

RSVD

RSVD

RSVD

RSVD

RSVD

RSVD

RSVD

Bit 7

6

5

4

3

2

1

0

Data Format

Velocity

RSVD

RSVD

RSVD

RSVD

Filter Enable Bit