3

Installation & Programming Manual

Chapter 1: Introduction & Overview

Move Time

This value is used when the input is configured as a movement detect. This value is the time that

movement should be detected after the input has gone high.

No Move Time

This value is used when the input is configured as a movement detect. This value is the time that

no movement should be detected after the input has gone low.

Command Bit Register

The command bit register is used for programming and clearing error flags. This bit register

is monitored continuously. Any 0 to 1 transition will cause the 1746L to act. (See Page 7:

Command Bit Register for details)

Programming Bit

A programming bit is set to indicate to the 1746L that there is new data in the output image table.

When the 1746L LDT Interface Module detects a low to high transition on this bit, it reads the

data in the output image table and programs the correct parameters.

Inch/mm Conversion

This bit will indicate whether the unit of measurement is in inches or mm (millimeters). When

this bit is set, the position and velocity data is reported back in mm to the hundredth decimal

place. When this bit is cleared, the unit of measurement will be reported back in inches to the

thousandth decimal place.

The input image table is used to monitor the data from the 1746L PLC LDT Interface Module.

There are 8 words associated with the input image table.

Position

The position of each LDT is sent back to the SLC 500 processor through the input image table.

The position takes up two words in the input image table and can range from -2,147,483.648 to

2,147,483.647 inches. However, the 1746L LDT Interface Module is designed to work in the

positive range only. For 1746L with two LDT positions, there are two separate positions shown

in the input table, each 2 words in length.

Velocity

The velocity of each LDT will be sent back to the SLC 500 processor through the input image

table. The velocity will take up 1 word in the table. For cards with two LDT inputs, there will

be two separate velocity values shown in the input image table. The velocity will range from

-32.768 to 32.767 in/s.

Status Bit Register

A Status Bit Register will show various flags for the LDT input card. (See page 12 for Status Bit

Register details).

1.3: Input Image Table