Chapter 1: Overview

Operating Manual

2

TIME UP/TIME DOWN

This switch determines the direction of the test. In the

TIME DOWN position you are performing a standard test

according to OSHA requirements. The switch should be in

the TIME UP position when checking press top stop.

STOP TIME (mSEC)/

This switch is used to select the display mode, either time or

SAFETY DISTANCE (IN) distance. Time is measured in milliseconds and distance is

measured in inches.

FULL REV/PART REV

This switch is used to determine the press clutch operation

mode, either full or part revolution. The majority of tests

are run in the part revolution mode.

CONTROL START

Known as CSP, this dial is used to set the point in the

POINT (IN)

stroke at which the command to start timing and fi res

the Auto-Hand is g iven. When the CSP dial is turned

clockwise, the dial will increment and de-increment when

turned counterclockwise. The CSP dial reads in tenths of

an inch. Example: 123 equals 12.3”.

MANUAL START

This jack is used with the optional manual start switches.

AUTO-HAND

This connector is used to connect the Auto-Hand to the

Safetimeter.

1.2: Theory of Operation

The P/V transducer measures the open height of a press. When this measurement
coincides with the preset CSP position, and the ram is traveling in the direction
selected on the TIME UP/TIME DOWN switch, the Auto-Hand will release one of the
two run controls or press an E-STOP control to initiate the press stop. When the
ram stops, the P/V transducer sends a stop signal to the Safetimeter and the meter
displays either stop time or safety distance, whichever display mode was selected
prior to the test.

NOTE: No OSHA standard exists for defi ning when a press has stopped (at what

ram velocity). The Safetimeter ends its measurement when the ram velocity
is approximately .17 inches per second (10 inches per minute). When
measuring stop time, you must take into account all elements and devices
used to bring the ram to rest. These include the “fl ight time” of the run and
E-STOP buttons (time for switch to activate), control relays, solenoids valves
and clutch and brake mechanical elements. Where an electronic guard (light
curtain) is used, response time of the device and the depth penetration factor
must be added to that measured by the Safetimeter before calculating safety
distance. Response time is generally stated by manufacturers of electronic
guards. However, to verify systems, the Auto-Flag can be used.