Status led's/programming keys, Variable pulse (fmip01) input option v1, Ldt input (fmip02) input option l1 – AMETEK 2110 Shut Height Monitor User Manual

Page 9

Advertising
background image

Installation and Programming Manual

4

Chapter 2: Hardware Overview

5

Installation and Programming Manual

Chapter 2: Hardware Overview

Variable Pulse (FMIP01) Input Option V1

This module is used with an LDT that provides its output in the form of a pulse width modulated
RS-422 signal. The module only works with Gemco 951VP2110 LDT’s.

LDT Input (FMIP02) Input Option L1

This module will accept an output from a controlled pulse, start stop pulse or variable pulse
magnetostructive LDT. This card accepts a wide range of LDT inputs and faster updates than
the variable pulse described above.

It allows the shut height monitor to receive the signals from the LDT. The pulse width signal
is converted to position data which the monitor displays and uses for shut height position. The
module also provides +24 VDC to supply power to the LDT. The monitor was designed to
work with the Gemco Series 951 or 952 LDT. However, other LDTs can be used with the shut
height monitor. If you are using a different type of LDT, contact the factory for wiring and
programming instructions.

The shut height monitor has 10 status LEDs and four programming keys. The LEDs provide
information on the monitor’s state during machine operation. The programming keys are used
to program functions and perform basic operations.