Plug top driver adjustment location guide, Current command block diagram, Voltage command block diagram – High Country Tek Plug Top Driver Series User Manual

Page 5

Advertising
background image

Electronic Controller Solutions for the Fluid Power Industry

Plug Top Driver adjustment Location Guide:

PWM

F.E.T.

output

stage

I Max ( 20 Turn potentiometer )

‘Dither’ ( PWM )

frequency adjust

I Min adjust

Ramp UP

Ramp

DOWN

+V Supply

GND (0v)

Command

Sig + I/P

Internal

PSU

Current

Feedback

PWM ‘ f ’

generator

Output to

valve coil

interface

Command

Scaling

Ramp

Generator

+Vref O/P

Current Command Block Diagram:

PWM

F.E.T.

output

stage

I Max ( 20 Turn potentiometer )

‘Dither’ ( PWM )

frequency adjust

I Min adjust

Ramp UP

Ramp

DOWN

+V Supply

GND (0v)

Command

Sig + I/P

Internal

PSU

Current

Feedback

PWM ‘ f ’

generator

Output to

valve coil

interface

Command

Sig - I/P

250Ω

shunt

Ramp

Generator

Voltage Command Block Diagram:

RED - +V Supply Input
BLUE - GND (0V) Supply Input
GREEN - +ImA Current Input
YELLOW - -ImA Current Input

NOTE:

-ImA current input is INTERNALLY
connected to GND (0v) supply input and
is NOT isolated.

IMPORTANT NOTE:

DO NOT short circuit the +Vref to +Supply
or GND(0V) as damage to the PTD will
occur!

RED - +V Supply Input
BLUE - GND (0V) Supply Input
GREEN - Voltage Command I/P
YELLOW - +Vref output to user

1.

Ramp UP - single turn potentiometer

2.

Ramp DOWN - Single turn Potentiometer

3.

Imin adjust - single turn potentiometer

4.

Dither Freq. - single turn potentiometer

5.

Imax - 20 turn potentiometer


ALL potentiometers are clockwise to
increase their setting

Fully Anti-Clockwise = ~100Hz
Fully Clockwise = ~250Hz

Cmd

Clockwise adjustment =
Higher I Min.

‘I Min’

adjustment.

I

out

Clockwise adjustment =
Slower ramp UP.

Output Current

Adjustment ‘I Max’

t

Clockwise adjustment =
Increase Output Current

‘Output ON’ led

Ramp ‘UP’ adjustment.

Ramp ‘DOWN’ adjustment.

t

Clockwise adjustment =
Slower ramp DOWN.

Dither Frequency

Adjustment.

Advertising