Parameter list, Closed-loop valve controller – High Country Tek DRF Series User Manual

Page 10

Advertising
background image

021-DRF Rev A

DRF User Manual

10

Copyright © High Country Tek, Inc.

– 2013

DRF

Closed-loop Valve Controller

Parameter List

The following table outlines the DRF parameters as well as the limits and units of measure for each parameter.

Parameter

Limits

Units

DRFx-xxx

Version #

C1 Mode

See Mode Description

Mode #

C1 Proportional gain

0.0 to 100

%

C1 Integral gain

0.0 to 100

%

C1 Derivative gain

0.0 to 100

%

C1 PID loop time

1 to 30

Cycles

C1 Deadband

0.0 to 2.0

V (mA)

Previous 5 parameters repeated for channel 3

2

C1 Min input

-10 to +10.0; 4 to 20.0

V (mA)

C1 Max input

-10 to +10.0; 4 to 20.0

V (mA)

C1 Min output

0 to 600

1

mA

C1 Max output

0 to 600

1

mA

C1 Ramp up

0.0 to 120.0

Seconds

C1 Ramp down

0.0 to 120.0

Seconds

Previous 6 parameters repeated for all channels

2

Dither frequency

30 to 1000

Hz.

C1 Command input

V (mA)

C1 Output current

mA

Previous 2 parameters repeated for all channels

2

Supply voltage

Volts

Fault status

Fault

1

0 to 1.2 A for

–12A version, 0 to 2.5 A for –25A version

2

Parameters starting with C1 are repeated for each channel and are displayed as C2 to C4