Braking and winding devices – OZ Lifting Products OZ Builder's Hoist OM User Manual

Page 10

Advertising
background image

Braking and Winding Devices

BRAKING

• Braking is via a mechanical brake and an electronic generated brake. The brake distance from time of

braking until stopping completely should be within 1.5 % of rope length wound during 1 minute.

This can be determined by simply timing the amount of rope that is wound in 1 minute and calculated by

1.5%.

• The rope speed with no load is faster than that with the rated load. The brake distance with no load will be

longer, but still within 1.5% of rope length

OVER-WINDING LIFT PREVENTION DEVICE

• A special mechanism prevents over-winding when lifting. When the swivel hook touches the limit lever,

lifting is automatically stopped.

• If the limit lever is set too close to the hoist body, it will cause serious damage to the limit lever and hoist

body.

• A suggested distance(s) between the limit lever and hoist body is as follows:

REVERSE-WINDING PREVENTION DEVICE

A special mechanism prevents reverse over-winding:

• When lowering if the rope is fully extended, this device will cause the wire rope to shift its position from

the front, toward the back.

• To disengage this device the wire rope needs to be shifted back to the front position. To do this pull and

hold the rope downward and press the button.

pg.10

Product #

OBH-500

Distance

3.14” - 3.93”