NOTE FOR THE REPLACING OF MEMORY IC

If a service repair is undertaken where it has been required to change the MEMORY IC, the following steps should be taken to
ensure correct data settings while making reference to TABLE 1.

Table 1

ADDRESS

DATA

ADDRESS

DATA

ADDRESS

DATA

ADDRESS

DATA

ADDRESS

DATA

CC

F1

D6

80

E0

76

EA

51

F4

41

CD

44

D7

00

E1

5E

EB

5F

83

F5

CE

24

D8

71

E2

08

EC

09

F6

3D

CF

88

D9

9F

E3

F0

ED

F0

F7

6B

D0

92

DA

02

E4

01

EE

05

0B

F8

D1

45

DB

0A

E5

F3

EF

F3

F9

0C

D2

00

DC

42

E6

6C

F0

00

FA

04

D3

02

DD

35

E7

2B

F1

2F

FB

3A

D4

09

DE

A3

E8

21

F2

DF

FC

99

D5

03

DF

56

E9

15

F3

41

3.

4.
5.
6.
7.
8.
The unit will now have the correct DATA for the new MEMORY IC.

ADDRESS

DATA

1.
2.

Turn on the POWER and press both FF key and CH UP key on the set for more than 2 seconds.
ADDRESS and DATA should appear as FIG 1.

Fig. 1

ADDRESS is now selected and should "blink". Using the SET + or - keys on the remote, step through the ADDRESS until
required ADDRESS to be changed is reached.
Press ENTER to select DATA. When DATA is selected, it will "blink".
Again, step through the DATA using SET + or - until required DATA value has been selected.
Pressing ENTER will take you back to ADDRESS for further selection if necessary.
Repeat steps 3 to 6 until all data has been checked.
When satisfied correct DATA has been entered, turn POWER off (return to STANDBY MODE) to finish DATA input.