4.2

SECTION 4 - MAINTENANCE

4.2 DAILY MAINTENANCE

Your Summers field sprayer will give you better service and last longer if it is properly maintained.

1. Grease all points shown.

2. Check all hydraulic components for leaks.

3. Check all sprayer system components for leaks.

4. Clean sprayer system strainer.

5. Check tank hold down straps.

6. Check nozzle patterns. If a nozzle pattern is distorted:

a. Remove nozzle tip.

b. Clean with tooth brush, wooden or plastic probe. Never use a metal object since damage

will occur.

c. Blow out nozzle tip with compressed air no greater than 40 psi. Never use your mouth to

blow out a nozzle tip.

d. Replace nozzle tip if necessary.

e. Install nozzle tip back onto sprayer.

7. During periods of use in freezing temperatures:

a. (Flush entire sprayer system with 100% RV antifreeze.) RV antifreeze is nontoxic and safe

for the environment. It must be used in 100 percent concentrations, but it is more economi-

cal then permanent antifreeze to purchase and will not corrode plastic spray components.

Read and follow antifreeze container instructions.

b. Spray solution through nozzles.

c. Allow dripless nozzles to drain by loosening each diaphragm check valve nut. With both

booms in transport position liquid accumulates near the boom pivot point. To permit drain-

age, remove the boom end cap or end nozzle and supply hose from each boom.

8. When changing chemicals, follow chemical manufacturers’ WARNINGS, instructions and proce-

dures concerning sprayer system cleaning.

4.3 OFF SEASON STORAGE

1. Clean main tank and optional mix and fill tank:

a. Flush each tank with clean water, then drain.

b. Wash each tank using a strong detergent

and mop, then drain.

c. Rinse each tank with clean water, then drain.

2. Clean entire sprayer system:

a. Partially fill each tank with clean water and add one part household ammonia for every 100

parts water.

b. Start pump and circulate solution through entire sprayer system. Spray solution through

nozzles, then drain.

3. Winterize entire sprayer system:

a. (Flush entire sprayer system with 100% RV antifreeze.) RV antifreeze is nontoxic and safe

for the environment. It must be used in 100 percent concentrations, but it is more economi-

cal then permanent antifreeze to purchase and will not harm plastic spray components.

Read and follow antifreeze container instructions.

b. Spray solution through nozzles.

c. Allow dripless nozzles to drain by loosening each diaphragm check valve nut.