Chapter 5

30

SCS 450 Serial Interface Installation & Service Manual

7.

Enter the adjusted Speed Cal value.

8.

Recheck the new Speed Cal value by repeating the steps above.

Refining the Speed Cal Value - Phoenix 10 Speed Sensors Only

The initial Speed Cal value when using the Phoenix 10 speed sensor is 785 [200]. However, after initial console
programming, it may be necessary to refine this number to improve the system’s performance. Complete the
following steps to refine the speed cal value:

1.

Verify the SCS 450 console is powered ON.

2.

Press the DISTANCE button on the SCS 450 console.

3.

Enter 0 as the value.

4.

Drive 1 mile [1 km].

Note:

Do not use the vehicle’s odometer to determine the distance. Use highway markers or section
lines to measure the distance traveled. To achieve the most accurate calibration, accelerate and
decelerate slowly.

5.

Check the value in the display. It should be approximately 5280 [1000]. If the value is between 5260 - 5300
[990 - 1010], the speed cal value for the machine is 785 [200]. If the value is any other value, use the
following formula to recalculate the speed cal value.

For Example:

Assume that the DISTANCE value is actually displayed as 5000 [980].

Important:

The new Speed Cal value must be rounded to the nearest whole number.

6.

Enter the adjusted Speed Cal value.

7.

Recheck the new Speed Cal value by repeating the steps above.

Changing Initial Console Programming

Occasionally it is necessary to make changes to the console programming after the initial programming is
complete. To make changes to the initial setup:

1.

Press SELF TEST and hold it for 30 seconds. The console’s display will flash the current program setting.

2.

Press CE to advance to the setting that needs to be changed.

3.

Press ENTER. The name of the variable being changed will appear in the console’s display.

4.

Change the variable to the desired setting.

5.

Complete the data entry by pressing ENTER.

6.

Repeat the steps above for each variable that needs to be changed.

Old SPEED CAL X 5280

=

Adjusted Speed Cal

DISTANCE VALUE

785 X 5280

=

743.4 (English)

5000

[200] x [1000]

=

204.1 [metric]

[980]

Advertising