Maintenance, Warning, Electric shock can kill – Hot Max Torches PL-25 User Manual

Page 14: Regular maintenance

Advertising
background image

Maintenance

KDAR Company

Electric Shock Can Kill

Only qualified personnel should attempt to install this equipment.

Turn off the input power at the fuse box or disconnect switch and discharge capacitors
before working inside the equipment.

Take care not to touch electrically hot parts.

Warning

Regular Maintenance


Note: Disconnect power to the unit before performing any maintenance.


With Each Use:

Check Gas/Air Pressure

Check the torch tip, electrode, air diffuser and outside nozzle.

Keep area around the machine clean and free of debris that could restrict the air flow of the cutter.

Clear air trap by pushing up on the valve at the bottom of the trap and allow air to purge the water.


Every Three Months.

Check and service air filter and trap.

Inspect the torch cable for damage and replace if necessary

Insure there are no kinks in the air line.

Check the torch body for cracks or damage that may cause problems.


Every Six Months

Examine the case for cracks or dents and repair as needed. It is important to keep the case in good
condition to protect internal components.

Blow out or vacuum the unit to insure proper air flow during operation.