RME DSP System Multiface User Manual

Page 29

Advertising
background image

User's Guide HDSP System Multiface II

© RME

29

I/O Box
Disconnect interrupts the communication between I/O-box and PCI or CardBus card. In case
the Multiface has been configured using the Settings dialog and TotalMix, Disconnect allows to
use it Stand-Alone (without a connected computer), after a power supply has been attached.

The status display below shows the current state of the I/O-boxt:

Error:

I/O-box not connected or missing power


Detected:

The interface has found an I/O-box and tries to load the firmware


Connected:

Communication between interface and I/O-box operates correctly


Disconnected:

Communication between interface and I/O-box has been interrupted, I/O-box
continues operation


Clock Mode
The unit can be configured to use its internal clock source (Master), or the clock source pre-
defined via Pref. Sync Ref (AutoSync).

Pref Sync Ref
Used to pre-select the desired clock source. If the selected source isn't available, the unit will
change to the next available one. The current clock source and sample rate is displayed in the
AutoSync Ref display.

The automatic clock selection checks and changes between the clock sources Word Clock,
ADAT optical, ADAT Sync and SPDIF.

Word Clock Out
The word clock output signal usually equals the current sample rate. Selecting Single Speed
causes the output signal to always stay within the range of 32 kHz to 48 kHz. So at 96 kHz
sample rate, the output word clock is 48 kHz.

Time Code
Time Code from the input ADAT Sync. Not available for the Multiface II.

System Clock
Shows the current clock state of the HDSP system. The system is either Master (using its own
clock) or Slave (see AutoSync Ref).

SyncCheck
SyncCheck indicates whether there is a valid signal (Lock, No Lock) for each input (Word
Clock, ADAT, SPDIF), or if there is a valid and synchronous signal (Sync). The AutoSync Ref-
erence
display shows the input and frequency of the current sync source.

Advertising