Troubleshooting procedures – Amana AK2T30/36E1/W1 User Manual

Page 17

Advertising
background image

Troubleshooting Procedures

RS2420002 Rev. 5

17

Indicator Lights and Diode Assembly

Some Models

Power Connected
1. Set meter to measure at least 250 VAC. Connect one

meter lead to P of control and the other to L2.

2. Connect cooktop to power source. Turn on control.
3. Meter should indicate 240 VAC. If it does not, replace

control.

4. If meter indicates 240 VAC and indicator does not

light, move lead from P of control to terminal D of
terminal block.

5. If meter does not indicate any voltage, then the diode

is an open circuit or a wire harness has a broken
wire. Test diode and wire harness for continuity.

6. If a short exists in the diode, all indicator lights will

come on when one control is turned on.

7. Replace diode or light assembly as required.

NOTE: Test diode, disconnect wires and connect meter

on 10 K

scale. Meter should indicate continuity

with leads connected one direction and no
continuity with leads in the reverse direction for a
diode to be operating properly. If no continuity,
diode is open. If continuity in both directions,
diode is shorted. In either case, replace diode.