Signals and interfacing – Clary GT Series User Manual

Page 14

Advertising
background image

T H E C O N T I N U O U S P O W E R C O M P A N Y

Page 14

SIGNALS AND INTERFACING

t the rear of the unit are two DB-9
subminiature, female connectors. These are
provided for communications links to a
computer or sophisticated monitoring device.

SIGNAL provides open-collector outputs that
typically signal Utility Interrupt and Low Battery
conditions. A system shutdown feature is also
available on this port. Applying a short between Pin
6 and Pin 7 will cause the system to shutdown in
battery mode. This conserves the battery life once

an orderly shutdown has been accomplished. The
system may be configured to shutdown by applying
a +5 to +12V signal across the appropriate pins.
Contact the factory for configuration details.
RS232 is a true computer communications signal
port.
The open-collector signal outputs can be converted
to dry contact closures, as an option. Below is the
pin out of the two connectors with their default
assignments:

OPEN-COLLECTOR CONNECTOR (SIGNAL)

2-

UTILITY INTERRUPTED SIGNAL

4-

COMMON SIGNAL RETURN

5-

LOW BATTERY SIGNAL

6-

+ UPS SHUTDOWN

7-

- UPS SHUTDOWN

RS232 CONNECTOR

2-

TRANSMITTING DATA (TX)

3-

RECEIVING DATA (RX)

6 & 8- DATA SET READY

5- SIGNAL

GROUND

A

DB-9F

SYSTEM
SHUTDOWN

-

+

5

6

9

1

LOW BATTERY

UTILITY INTERRUPTED

SIGNAL: OPEN-COLLECTOR CONTACT

CONNECTOR

DB-9F

SYSTEM
SHUTDOWN

-

+

5

6

9

1

INVERTER ACTIVE

LOW BATTERY

UTILITY INTERRUPTED

SIGNAL: DRY CONTACT CLOSURE (OPTION)

CONNECTOR

RS232 CONNECTOR

GND

5

3

TX

RX

2

6

8

DB-9F

1K

+5V

DSR