9 piezo buzzer – Matrix Orbital GLK240128-25 User Manual

Page 43

Advertising
background image

38

Command Summary

6.9 Piezo Buzzer

9.1 Activate Piezo
Buzzer*

Dec
Hex
ASCII

254 187

FE BB

■ ╗

Frequency Time
Frequency Time
Frequency Time

v8.0

Activates a buzz of specific frequency from the onboard piezo buzzer for a specified length of time.

Frequency

Short

Frequency of buzz in hertz.

Time

Short

*

Duration of the beep in milliseconds.

*Note:

When a beep precedes a delay command, the duration of the beep must be shorter than that of the delay.

9.2 Set Default
Buzzer Beep

Dec
Hex
ASCII

254 188

FE BC

■ ╝

Frequency Duration
Frequency Duration
Frequency Duration

v8.3

Set the frequency and duration of the default beep transmitted when the bell character is transmitted.

Frequency

Short

Frequency of the beep in Hertz, default 440Hz.

Duration

Short

Duration of the beep in milliseconds, default 100ms.

9.3 Set Keypad
Buzzer Beep

Dec
Hex
ASCII

254 182

FE B6

Frequency Duration
Frequency Duration
Frequency Duration

v8.4

Set the frequency and duration of the default beep transmitted when a key is pressed.

Frequency

Short

Frequency of the beep in Hertz, default is 0 or off.

Duration

Short

Duration of the beep in milliseconds, default is 0 or off.

9.4 Set Touch
Buzzer Beep

Dec
Hex
ASCII

254 182

FE B6

Down Freq Up Freq
Down Freq Up Freq
Down Freq Up Freq

v8.4

Set the frequency of the default beep transmitted when a touch event occurs. Duration of each is 50ms.

Down Freq

Short

Frequency of the down event beep in Hertz, default is 0 or off.

Up Freq

Short

Frequency of the up event beep in Hertz, default is 0 or off.


Advertising
This manual is related to the following products: