2 fan and gpo commands – Matrix Orbital PK202-24-USB User Manual

Page 26

Advertising
background image

Table 10: Continued / Size Byte

Bit Description

7

Continued

6

5

4

3

Packet Size

2

1

0

Table 11: Display Return Protocol Types

Decimal

Hex

ASCII

Description

49

0x31

’1’

1-Wire data

82

0x52

’R’

Fan RPM data

5.2 Fan and GPO Commands

5.2.1 General Purpose Output Off (254 86 [gpo #])

This command turns OFF any of the general purpose outputs. [gpo #] is 1 to 6.

5.2.2 General Purpose Output On (254 87 [gpo #])

This command turns ON any of the general purpose outputs. [gpo #] is 1 to 6.

5.2.3 PWM Value (254 192 [fan #] [PWM value])

This command sets one of the high power GPOs (GPOs 1-3) into PWM mode. This permits speed

control of a fan. A PWM value of 0 is off, 128 is 50% power, and 255 is full power. The fan # can be 1 to 3.

5.2.4 Return Fan RPM (254 193 [fan #])

This command will return a packet to the host with the fan RPM contained in it. The structure of the fan

is described in the Table below.

Matrix Orbital

PK202-24-USB

22

Advertising