7.1.6 Display off (254 70) (R)

This command turns the display off.

7.1.7 Load Startup Screen (254 64 [40 characters])

This command sets and memorizes the startup screen which will appear each time the display is turned

on. By default the screen shows;

Table 20: Default Screen

Matrix Orbital

PK202-24-USB

The 40 characters define the two 20 character rows of the screen.

Table 21: Default Screen

Character 1

Character 20

Character 21

Character 40

If sending more then 10 characters to be stored, add in ~10ms per character delay. Predefined custom

characters can be used in the “Startup screen” as well, by using 0x00 through 0x07 characters.

7.1.8 Read Module Type (254 55)

This command will return the model type value of the module as a 1 byte hex value. Values for various

modules at the time of this publication are as follows;

Table 22: Module Values

LCD0821 - 0x01

LCD2021 - 0x03

LCD2041 - 0x05

LCD4021 - 0x06

LCD4041 - 0x07

LK202-25 - 0x08

LK204-25 - 0x09

LK404-55 - 0x0A

VFD2021 - 0x0B

VFD2041 - 0x0C

VFD4021 - 0x0D

VK202-25 - 0x0E

VK204-25 - 0x0F

GLC12232 - 0x10

GLC24064 - 0x13

GLK24064-25 - 0x15

GLK12232-25 - 0x22

LK404-AT - 0x31

LK402-12 - 0x33

LK162-12 - 0x34

LK204-25PC - 0x35

LK202-24-USB-0x36

VK202-24-USB - 0x37

LK204-24-USB - 0x38

VK204-24-USB - 0x39

PK202-24-USB-0x42