3-7. Inverter Operation

To operate the power inverter, use the ON / OFF switch on the Front panel to
turn the power on. Then the power inverter is ready to deliver AC power to
the loads.
If you are operating several loads from the power inverter, turn them on
separately after the inverter is on.
This will ensure that the power inverter does not have to deliver the starting
currents for all the loads at one time.

3-7-1. Controls and indicators:

The ON / OFF switch turns the control circuit in the power inverter on
and off. It does not disconnect power from the power inverter.
The Inverter operates from an input voltage ranging of:

10.5 to 15.0 VDC for 12V models

21.0 to 30.0 VDC for 24V models

42.0 to 60.0 VDC for 48V models

The Inverter will indicate high and low DC voltage conditions as
follows:

Model

Dc Input over

Voltage shut-down

Dc Input under

Voltage alarm

Dc Input under

Voltage shut-down

S600-112
S600-212

15.3 11.0 10.5

S600-124
S600-224

30.6 22.0 21.0

S600-148
S600-248

61.2 44.0 42.0