Appendix F. Reading Voice Code in a *.DLD File

F-3

F.3 Modem Security Enabled

LoggerTalk’s Modem Security Code is unrelated to the
Datalogger’s *C mode passwords. Refer to the datalogger
operator’s manual for more information on the datalogger’s *C
mode.

This last example uses the modem security code "1234" to allow access to the
second level menu. Notice the characters following the "?" at the beginning of
the character stream. The security code will always be the very first thing in
the imbedded character portion of the *.DLD file.

;|?1234#"☺56&☺57&"#

#"☺53&"#

#"☺52&"#

>\4☺88&☺89&☺109&☺74&☺71&☺71&☺71&"☺109&☺135&☺86&
"☺85&$3☺87&☺122&.\

\4"☺109&☺98&☺191&"☺85&$1☺192&.\

This code translates to:

(security code 1234) Input Locations

Ports

Flags

(4 decimal places) Campbell Scientific Datalogger Program (pause)
(pause) (pause) "Datalogger Internal Temperature" Is (input location 3)
Degrees Fahrenheit.

(4 decimal places) "Datalogger Battery Voltage" Is (input location 1)
Volts.