COM320 Voice Communications Modem

' Monitors a value
Sub SubKey1
Do

VoiceSpeak ("50MS PRESS SENSOR NUMBER 50MS PRESS STAR TO RETURN", 0)

mykey = VoiceKey (KeyTimeout)

If mykey = 1 Then VoiceSpeak ("50MS THE BATTERY VOLTAGE IS" + Value(1) + "VOLTS", 1)

If (mykey = 2) Then VoiceSpeak ("50MS THE REFERENCE IS" + Value(2) + "DEGREES", 1)

If (mykey = 3) Then VoiceSpeak ("50MS THE T C IS" + Value(3) + "DEGREES", 1)

Loop

'

Sensor

value

loop

EndSub

' Read a port and possibly toggle
Sub SubKey2

Do ' Until * or timeout

Dim keybit,port As Long,state

VoiceSpeak("50MS PRESS PORT NUMBER 50MS PRESS STAR TO RETURN", 0)

port

=

VoiceKey(keyTimeout)

If (port > 0) AND (port <= 8) Then

keybit = 2^(port-1) ' Bit 0..7 is set in keybit. Keybit = 2^(port-1).

Do

ReadIO(state,

&b11111111)

VoiceSpeak("50MS C" + port + "IS",0)

If

state

AND

keybit

Then

VoiceSpeak("ON",0)

Else

VoiceSpeak("OFF",0)

EndIf

VoiceSpeak("50MS

PRESS

POUND

TO TOGGLE 50MS PRESS STAR TO RETURN", 0)

If

VoiceKey(KeyTimeout) = POUND Then

ReadIO

(state,&b11111111)

If

state

AND

keybit

Then

state

=

state

AND

(NOT

keybit)

Else

state

=

state

OR

keybit

EndIf

WriteIO(&b11111111,state) ' Toggle control port

EndIf

Loop
EndIf
Loop
EndSub

‘ Read a flag and possibly toggle
Sub SubKey3

Const NUMBERFLAGS = 8

Public

Flags(NUMBERFLAGS)

Do ' Until * or timeout

VoiceSpeak("50MS PRESS FLAG NUMBER 50MS PRESS STAR TO RETURN", 0)

mykey

=

VoiceKey(keyTimeout)

If (mykey > 0) AND (mykey <= NUMBERFLAGS) Then

Do

VoiceSpeak("50MS FLAG" + mykey + "IS",0)

8