Appendix C. CS I/O 9 Pin Serial Port

C-2

TABLE C-1. Pin Description

ABR = Abbreviation for the function name.

PIN = Pin

number.

O

= Signal Out of the datalogger to a peripheral.

I

= Signal Into the datalogger from a peripheral.

PIN

ABR

I/O Description

1

5V

I

5 VDC supply (not used for COM320).

2

SG

Signal Ground: Provides a power return for pin 1
(5V), and is used as a reference for voltage levels.

3

RING

O

Ring: Raised by the modem to put the datalogger
in the telecommunications mode.

4

RXD

O

Receive Data: Serial data transmitted by the
modem are transmitted on pin 4.

5

ME

I

Modem Enable: A logic high internally switches
power to the modem. A logic low internally
powers down the modem.

6

SDE

I

Synchronous Device Enable: A logic high
disables communication with the modem, without
removing power or changing the modem’s mode.

8

TE

I

+12 VDC power supply.

9

TXD

I

Transmit Data: Serial data are transmitted from
the datalogger to the modem on pin 9; logic low
marking (0V) logic high spacing (5V) standard
asynchronous ASCII, 8 data bits, no parity, 1 start
bit, 1 stop bit, 300, 1200, 9600, 76,800 baud (user
selectable).