4.2.3 Step 3: Connect

You are now ready to connect to your datalogger using the LoggerNet Connect

Screen.

Datalogger program transfer, table-data display, and data collection are now

possible.

4.3 Programming the Datalogger to Send Data to the NL115

The

CardOut() instruction is used in the datalogger program to send data to

the CF card.

CardOut() must be entered within each DataTable declaration

that is to store data on the CF card. The file is saved on the card with the name

stationname.tablename and a .DAT extension.

The

CardOut() instruction has the following parameters:

StopRing: A constant is entered for the StopRing parameter to specify whether

the

DataTable created should be a ring-mode table (0) or a fill-and-stop table

(1).

Size: The Size parameter is the minimum number of records that will be

included in the

DataTable. If –1000 is entered, the size of the file on the card

will be the same as the size of the internal table on the datalogger. If any other

negative number is entered, the memory that remains after creating any fixed-

size tables on the card will be allocated to this table. If multiple DataTables are

set to a negative number, the remaining memory will be divided among them.

The datalogger attempts to size the tables so that they will be full at the same

time.

In the following example, the minimum batt_voltage and a sample of PTemp

are written to the card each time the data table is called. The StopRing

parameter is 0 for ring mode. This means that once the data table is full, new

data will begin overwriting old data. The size parameter is –1, so all available

space on the card will be allocated to the table.

DataTable(Table1,1,-1)
CardOut(0 ,-1)

Minimum(1,batt_volt,FP2,0,False)

Sample(1,PTemp,IEEE4)

EndTable

To prevent losing data, collect data from the CF card before

sending the datalogger a new or modified program. When

a program is sent to the datalogger using the Send button in

the Connect Screen of LoggerNet or PC400, an attribute is

sent along with the program that commands the datalogger

to erase all data on the CF card from the currently running

program.