Initial inspection, Quickstart, 1 physical setup – Campbell Scientific NL115 Ethernet Interface and CompactFlash Module User Manual

Page 8: Physical setup, 1. nl115 attached to a cr1000

Advertising
background image

NL115 Ethernet and CompactFlash

®

Module

An NL115 with a serial number less than 10297 requires a firmware

update to function properly when attached to a CR3000 datalogger with a

serial number greater than 6260. This update must be performed by

Campbell Scientific. If you require this firmware update, see the

Assistance

section at the front of this manual for information on returning

your NL115 to Campbell Scientific.

3. Initial Inspection

Upon receipt of the NL115, inspect the packaging and contents for damage.

File damage claims with the shipping company.

4. Quickstart

This section describes the basics of communicating via Ethernet and storing

and retrieving datalogger data. These operations are discussed in detail in

Section 7, Operation.

4.1 Physical Setup

Always power down the datalogger before installing to or

removing the NL115 from the datalogger.

After powering down the datalogger, plug the NL115 into the datalogger

peripheral port (see FIGURE 4-1). Attach Ethernet cable to the 10Base-T port.

If using the 28033 surge protector, connect the other end of the Ethernet cable

to the 28033 and connect another Ethernet cable to the other end of the 28033.

Restore power to the datalogger. Insert formatted CF card. (For instructions

on formatting a CF card, see Appendix A, CF Card Maintenance.)

A CF card does not need to be present in order to use the NL115’s

TCP/IP functionality.

FIGURE 4-1. NL115 attached to a CR1000

CAUTION

NOTE