4 pc208w configuration – Campbell Scientific RF400/RF410/RF415 Spread Spectrum Radio/Modem User Manual

Page 34

Advertising
background image

RF400 Series Spread Spectrum Data Radio/Modems

26

RF400

RF400

RF400

RF400

DATALOGGER

DATALOGGER

DATALOGGER

FIGURE 8. Point-to-Multipoint System

5.3.4 PC208W Configuration

a.

Point-to-point

(1) Device Map -

COM1

CR10X1

(2) Set station CR10X1 baud rate to 9600 baud in network map

(3) Datalogger extra response time – 0 mS

b.

Point-to-multipoint

(1) Device Map -

COM1

Generic1

10X3001
10X3005

(2) Set Generic Modem baud rate to 9600 in device map.

(3) Generic Modem Settings

(a)

√ “Make DTR Active”

(b)

√ “Hardware Flow Control”

(c) Extra Response Time (Standby Mode Max Response Delay +

200 ms; see Table D-1)

(i) 0 mS with 24 mA Standby Mode

(ii) 1200 mS with 1/2 sec cycle default Standby Mode delay

(iii) 4200 mS with 2 sec cycle Standby Mode delay

6 dBd Yagi

CS I/O

CS I/O

CS I/O

CS I/O

9 dBd Yagi

CS I/O

CS I/O

0 dBd Half-wave

3 dBd Omni Collinear

RS-232

AC Adapter

Advertising