Campbell Scientific RF400/RF410/RF415 Spread Spectrum Radio/Modem User Manual

Page 66

Advertising
background image

Appendix I. Phone to RF400 Series

I-2

c.

Phone Modem

1)

Baud Rate – 9600

2)

Modem Pick List – per PC’s phone modem

3)

Extra Response Time – 2000 ms

d.

Datalogger – Dialed Using Phone # at Base site

RF400 CONFIGURATION

a.

Base RF400

1)

Active Interface: “COM2xx to RF400”

2)

AT Command (Attention) Character: “-“

3)

All other settings: defaults

b.

Remote RF400 – leave all settings: defaults

Note: If there is a neighboring RF400 network, you should change
the Hopping Sequence of base and remote RF400s to a new setting to
avoid interference (see Section 5.3.1 for method to detect neighboring
network).

3.

POINT-TO-MULTIPOINT COMMUNICATIONS

PC-Modem ------------ COM210-PS512M-RF400 ------------ RF400-DL1

(null-modem)

------------

RF400-DL2

LoggerNet SETUP

a.

Setup:

ComPort_1

PhoneBase

PhoneRemote

RF400

RF400Remote

CR10X

RF400Remote_2

CR10X_2

b.

ComPort_1 – default settings

c.

PhoneBase

1)

Maximum Baud Rate – 9600

2)

Modem Pick List – per PC’s phone modem

3)

Extra Response Time – 0 s

d.

PhoneRemote – input base site’s phone number

e.

RF400 – make Attention Character: “-“ ; leave the rest defaults

f.

RF400Remote – make Radio Address: “1“ ; leave the rest defaults

g.

RF400Remote_2 – make Radio Address: “2“ ; leave the rest defaults

h.

Dataloggers – default settings, schedule collections as desired

Advertising