Installation – Campbell Scientific SDM-IO16 16-Channel Input/Output Expansion Module User Manual

Page 12

Advertising
background image

SDM-IO16 16 Channel Input/Output Expansion Module

SDM-IO16

DATALOGGER

GND

12 V

SDM-C1 or C1
SDM-C2 or C2
SDM-C3 or C3

a) Connection with Datalogger Supply

EXTERNAL

9 TO 18 VDC

SDM-IO16

DATALOGGER

12 V

GND

+ -

SDM-C1 or C1
SDM-C2 or C2
SDM-C3 or C3

(b) Connection with External Supply

FIGURE 3. Connection Block Diagrams

4. Installation

For correct operation the SDM-IO16 must be installed where there is no risk of
water ingress or condensation.

The order in which connections are made is critical.
Always connect 12 V first, followed by ground, then the
control ports.

CAUTION

The CABLE5CBL-L or a similar cable connects the datalogger to the
SDM-IO16. For datalogger connections, see Table 1, below. Please refer to
Figure 4 for details of how to use the spring-loaded terminals.

TABLE 1. Datalogger to SDM-IO16 Connections

Datalogger

Connection Order

SDM-IO16

CR800, CR850, CR1000,

CR10(X), 21X, CR7

CR3000, CR5000

First

12 V

12 V on datalogger or

external supply

12 V on datalogger or

external supply

Second

C1
C2
C3

or G

C1
C2
C3

G

SDM-C1
SDM-C2
SDM-C3

6