8.5.8 HC2S3 Rotronic Temperature and RH Probe

Mount the probe inside the 41003-5 10-plate radiation shield as shown in

FIGURE 8-19.

1. Insert the 27731 hex plug that ships with the HC2S3 probe into the

underside of the 41003-5 base.

2. Insert the probe into the radiation shield leaving about 2.5 cm (1 in)

exposed below the hex plug.

3. Tighten the hex plug such that it compresses against the body of the

HC2S3 to hold it inside the radiation shield.

4. Attach the probe to the cable by aligning the keyed connectors, pushing

the connectors together and tightening the knurled ring.

FIGURE 8-19. HC2S3 Temperature and RH Probe

41003-5

pn 27731 Hex Plug

U-bolt

CM200 Series Crossarm