Connections – Wesley BC-6200-8SA User Manual

Page 12

Advertising
background image

6

Curtis 1268 Manual,

Rev. D

CONNECTIONS

Low Current Connections

Three low current connectors are built into the 1268 controller. They are
located in a row on the top of the controller:

J1-

1

Keyswitch Input (KSI)

input and return for main contactor coil

J1-

2

Logic Enable

input from run/store switch

J1-

3

Fuse Sense

input from WalkAway

fuse sense line

J1-

4

Logic Power

power to controller logic

J1-

5

(not used)

J1-

6

(not used)

J1-

7

(not used)

J1-

8

Pedal Interlock Switch

input from pedal switch, wired to throttle

J1-

9

WalkAway™ Return

coil return for WalkAway

relay

J1-

10

Forward

input from forward switch

J1-

11

Reverse

input from reverse switch

J1-

12

(not used)

J1-

13

Pot High

+5V supply through 453Ω (or ITS input)

J1-

14

Pot Low

453Ω to ground

J1-

15

Pot Wiper

throttle wiper input (or ITS input)

J1-

16

LED Ground

ground for external LED

J1-

17

Main Contactor

contactor coil driver low-side output

J1-

18

Brake Light Driver

relay driver low-side output

J1-

19

Reverse Alarm

alarm low-side driver output

J1-

20

Mode Switch

input from mode switch

J1-

21

(not used)

J1-

22

External LED Driver

LED driver high-side output

J1-

23

Auxiliary Driver

WalkAway

/EMB driver low-side output

J1-

24

(not used)

The 24-pin connector provides the logic control connections. The mat-

ing connector is a 24-pin Molex Mini-Fit Jr. connector p/n 39-01-2245 using
type 5556 terminals. The appropriate wire gauge is 18–24 AWG.

2 — INSTALLATION & WIRING:

Controller

J1

J2

J3

J1

Logic connector

J2

Speed Sensor connector

J3

Programmer connector

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

J1