9

Standard Control Wiring

Wiring is shown in Figures 3a and 3b for the most commonly used components.
Wiring for alternative throttles is shown in the following pages.

The main contactor coil must be wired directly to the controller as shown

in Figures 3a and 3b. The controller uses the main contactor coil driver output
to remove power from the controller and motor in the event of various faults.
If the main contactor coil is not wired to Pin 17, the controller will not
be able to open the main contactor in serious fault conditions and the
system will therefore not meet EEC safety requirements.

2 — INSTALLATION & WIRING:

Controller

Fig. 3b

Standard wiring configuration for Curtis 1268 controller,

in an application with the WalkAway

function.

1268 CONTROLLER

PEDAL INTERLOCK

BRAKE LIGHT RELAY

J1-20

MODE (M1, M2)

J1-18

REVERSE ALARM

J1-19

POT HIGH

J1-13

POT WIPER

J1-15

POT LOW

J1-14

THR

O

TTLE PO

T

A

MAIN

REVERSE

FORWARD

J1-1

KSI

SPEED

SENSOR

J2-4
J2-5
J2-6

BATTERY

RUN/

STORE

SWITCH

(20 A)

B+

GROUND

+15V

M-

INPUT

B-

A1

A2

J3-1
J3-2
J3-3

PR

OGRAMMER

RX DATA

TX DATA

B-

J3-4

+15V

F1
F2

F1

F2

KEYSWITCH

J1-10

F

R

N

J1-11

J1-17

MAIN CONTACTOR

J1-16

J1-22

LED DRIVER

GROUND

+

-

J1-2

J1-4

LOGIC ENABLE

LOGIC POWER

CHARGER INTERLOCK

SWITCH (optional)

J1-8

J1-3

-

+

FUSE SENSE

J1-9

J1-23

WALKAWAY

FUSE

(20A)

WALKAWAY DRIVER

WALKAWAY RETURN