INSTALLATION OF THE SUPER

STATION

OR A STANDARD WALL PUSH

BUTTON

The Super Station (Deluxe Wall Pushbutton Station) is

a 7 function station designed to work with and

maximize the operation of your opener. Connection

to any other operator may damage the operator and/or

the Super Station. Only connet one Super Station to

the operator. Do not connect more than one Super

Station to the Operator.

If desired, a standard wall push button may be

installed and connected to your opener as an alternate

to the Super Station or in addition to the Super Station.

A standard wall push button is not included in your

hardware package, it can be purchased from your

professional installing dealer or a door bell button

[without light] can be substituted. The operating

parameters for the standard wall push button are

outlined on a page that follows to see if that mode of

operation is right for you. The Super Station is

included with your opener and it’s installation is

recommended, the Super Station will provide full

control over the garage door at all times.

YOU MAY CONNECT ONLY ONE SUPER

STATION PER OPERATOR -

ADDITIONAL STANDARD WALL PUSH

BUTTONS MAY BE CONNECTED TO THE

OPERATOR

STEP 1:

After determining a suitable location,

usually near the access door and at least 5 feet above

the floor to prevent use by children, use the Super

Station or the standard wall push button as a guide to

mark the mounting holes. Drill holes for drywall

anchors or screws. NOTE: Do not mount directly to

masonry walls. Use backer board.

of 2-conductor, #22 gauge wire (or heavier) is

required to connect either control to the garage door

operator. Strip approximately 2” of the wire jacket

from one end and 1/2” of insulation from each wire.

Carefully connect one wire to each of the two

terminals. Carefully tuck the loose wires into the case

and mount the unit using appropriate screws.

STEP 3:

Run the wire from the control to the

operator, supporting it at 18” intervals with suitable

staples. Leave a sufficient length to make the

necessary connections to the operator terminal strip.
WARNING: SOME LOCAL BUILDING CODES

DO NOT ALLOW SURFACE WIRING. BE

SAFE AND CHECK WITH YOUR LOCAL

BUILDING INSPECTOR FIRST.

STEP 4:

Ensure power is OFF to the opener or

disconnect the power from the opener. Strip

approximately 4” of jacket from the end of the wire

and 1/2” insulation from each wire.

Connect to terminals 0 and 1 as shown in

the illustration at left. Support the wire near

the

operator

with wire

ties.

See Step 5,
next page.

WARNING

A CHILD OPERATING THE DOOR

CONTROLS RISKS INJURY — OR

DEATH — TO HIMSELF AND OTHERS.

DO NOT ALLOW CHILDREN TO

OPERATE ANY DOOR CONTROLS.

MOUNT THE PUSHBUTTON AT LEAST

5 FT FROM THE FLOOR, OUT OF

REACH OF CHILDREN.

CONTROL AND AUXILIARY EQUIPMENT

WARNING

IMPROPER DOOR OPERATION

COULD CAUSE INJURY OR DEATH.

WARNING LABEL MUST BE

MOUNTED ON WALL NEAR THE

PUSHBUTTON. ALL WARNINGS AND

INSTRUCTIONS ON THE LABEL

SHOULD BE STRICTLY ADHERED TO.

!

Child can be pinned under automatic garage
door. Death or serious injury can result.

• Never let child walk or run under moving door.

• Never let child use door opener controls.

• Always keep moving door in sight.

• If person is pinned, push control button or use

emergency release.

• Test door opener monthly:

Refer to your owner’s manual

Place one-inch object (or 2x4 laid flat) on floor.

If door fails to reverse on contact, adjust opener.

If opener still fails to reverse door, repair or replace opener.

W AR N I N G

104350

CONTROL BUTTON

WARNING LABEL

PUSHBUTTON

4

3

2

1

0

TWO WIRE

OPERATOR

RECEIVER

TRANSMITTER

(DELUXE PUSHBUTTON)

SUPER STATION

T2

T1

PHOTOCELL SERIES CONNECTION (RECEIVER FIRST)

SAFE FINISH PHOTOSYSTEM

CONNECTIONS