12

Step-by-step installation guide

13

Step-by-step installation guide

NOTE: The house duct is needed to connect to the

exhaust adaptor after installation completion.

B1. ADAPTING mICROWAVE BLOWER

FOR RECIRCULATION

2. Lift up the

blower plate.

1. Remove and save screw

that holds blower plate to

microwave.

Back of

Microwave

NOTE: The exhaust adaptor with damper is not

needed for recirculating models. You may want to

save them for possible future use.

3. Remove screw holds blower mortor and

carefully pull out the blower unit. The wires will

extend far enough to allow you to adjust the

blower unit.

blower mortor screw

CAUTION: Do not touch blade of blower for

preventing crack and break. Hold outer case when

the blower pull out or back into.

4. Roll the blower unit 90 ° so that fan blade

openings are facing toward the front of the

microwave.

Back of

Microwave

Back of

Microwave

Before Roll

After Roll

5. Place the blower unit back into the opening.

CAUTION: Do not pull or stretch the blower unit

wiring. Make sure the wires are not pinched.

6. Secure blower unit to microwave with the screw.

B2. INSTALLING THE CHARCOAL

FILTER

1. Remove screws on top of grille using a #1

Phillips screwdriver.

2. Open the door.
3. Remove the grille.

• After push left, Pull the grille straight off.

Charcoal

Filter

4. Install the charcoal filter. When properly installed,

the wire mesh of the filter should be visible from

the front.

5. Reinstall the grille and the screws.
6. Close the door.

Insert mesh-side up

A. OUTSIDE TOP EXHAUST (VERTICAL DUCT)

B. RECIRCULATING (NON-VENTED DUCTLESS)

SMH8165_XAA DE68-03587A-04-EN_120725.indd 13

2012-07-25 �� 8:05:30