Trouble shooting, Gas model, Warning – Samsung DV231AGW-XAA User Manual

Page 9

Advertising
background image

9

GAS MODEL

TROUBLE SHOOTING

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before
servicing, unless testing requires power.

Radiant Sensor(10RS)
Resistance value < 1 Ω
If resistance is infinite, replace Radiant sensor

Igniter(101D)
Resistance value 40~400 Ω
If resistance is infinite, replace Igniter

Gas Valve(25M01A)
Valve 1-2 : Resistance value 1.2K Ω
Valve 1-3 : Resistance value 0.5K Ω
Valve 4-5 : Resistance value 1.2K Ω
If resistance is infinity, replace Valve

Thermostat (60T21 Hi-Limit)230F-50F
Resistance value < 1 Ω
If resistance is infinity, replace Thermostat

(Technical)DV431AEP-02365D-03_EN.indd 9

2012-04-26 �� 10:42:56

Advertising