TROUBLE DIAGNOSIS

• Read Lock Switch and PCB (CN2 & CN3). (Refer to PCB Connector Check.)

• Perform Quick Test Mode. Check Door Lock. Check the output voltage of Door Lock Coil.

If it reads 120V, change Door Lock Switch, and if not, change PCB. (Refer to PCB Connector Check.)

No Key Operation
• Option and Function buttons respond differently according to each cycle.

• Child Lock is being activated. To exit, hold down Soil Level Key and Signal Key simultaneously until it sends

out a beeping sound.

• When “End“ illuminates on the display, only Power button works. Press Power button and make new cycle

selections.

Will Not Drain
• Check for any kink on the drain hose. If any, straight it out.

• Check for any restriction in the drain hose.

• Close the door and press the Start/Pause Button. For safety reasons, the washer does not tumble or spin with

the door open.

• When it is freezing outside, check if it is frozen inside the drain hose.

• Check if the water level signal input is correct. Go to Board Input Test Mode.

• Go to Quick Test Mode and do Drain Pump Test.

• Check if there is any twist in the hose (the one between Tub and Drain Pump).

• Check if it reads AC 120V at the pump when a spin cycle is selected.

• Read the winding resistance of the pump motor. (14.2±7% Ohms)

• Check the pump at CN3(PIN3) on PCB. It should read AC 110~120V. (Refer to PCB Connector Check)