TROUBLE DIAGNOSIS

Wrong Water Temperature
• Check if both of the water taps are fully open.

• Make sure the domestic water heater is set to deliver water lower than 120°F (49°C) hot water at the tap.

Also check water heater capacity and recovery rate.

• If the water heater is located far from the washer, screw out the hot water tap and let its water pass until you

get hot water.

• Too Hot/Too Cold: Reduced amount of water is supplied while PCB controls the influx to regulate the actual

temperature of the water in the tub. This may appear to be significantly hotter/colder than expected.

• Check if the temperature selection is correct.

• Disconnect inlet hoses from the Water Valve and remove any residue in the inlet screens.

Noisy and/or Vibration/Walking
• Check if the washer is leveled and the lock nuts are tightened up on the bottom plate.

• Check if all of the shipping bolts and spacers are removed from the back panel.

• Check if load is big enough and there is no unbalance.If there is not enough load, put in a few towels to balance it.

• Check if the motor is fastened enough.

• Remove various trouble contributors (such as dust coat on the floor).

Rubber Feet Leaving Marks on Floor
• Use a pencil eraser to remove mark.
• Walk washer into location, do not drag.
Additive Cups Full of Water
• Small amount of water in bottom of additive cups is normal.
• Remove and wash Dispenser Tray, removable Cup, and Rinse Cap.
• Level washer.
Buttons do not Respond
• Option and Function buttons respond differently according to each cycle.

• Child Lock feature has been selected. To disable feature press and hold Temp and Spin simultaneously until a

beep is heard.

• When display shows “End”, only the Power button will function. Press Power and make new cycle selections.

TROUBLE SHOOTING

To avoid risk of electrical shock, personal injury or death; disconnect power to washer

before servicing, unless testing requires power.

WARNING