Thermistor Check

Check Resistance at Pin #1 and #2 of CN9

Tester Check = 47

Water Sensor Check

Check Frequency at Pin #4 and #2 of CN9

Reset frequency = 25.6kHz

Check Resistance at Pin #5 and #2 of CN9

Reset frequency = 25.6kHz

Motor Check

Check Voltage at Pin #1 of CN8 and Pin #2 of RY1

When motor operates CCW = AC 120V

Check Voltage at Pin #2 of CN8 and Pin #2 of RY1

When motor operates CW = AC 120V

Pump Check

Check Voltage at Pin #4 of CN6 and Pin #2 of RY1

When Drain Pump operates = AC 120V

Water Valve Check

Check Voltage at Pin #1,5 of CN6 and Pin #2 of RY1

When Valve operates = AC 120V

Heater Relay Check

Check Voltage at Pin #2 of RY1 and Pin #2 of RY2

When Heater Relay operates = AC 120V

AC Power Check

Check Voltage at Pin #2 of RY1 and Pin #1 of RY2

Tester Check = AC 120V