AXIS 240Q - Unit Connectors

Schematic Diagram - I/O Terminal Connector

o

z

o

z

z

z

o

o

o

z

o

o

o

o o

A

B

AXIS 240Q

Video Server

3.3V

PS-K 9V

e.g. push button

Device

GND PIN 5

RS-485

9

10

11

12

o

o

8

o

6

z

z

RS-232

D-SUB

o

5

o

4

o

3

o

2

Switch

Mode

Power

Supply

o

7

1

o

o

Relay

GND

+

COM Ports RS-232 and RS-485

The COM Ports RS-232 and RS-485 support several operational modes:

Generic TCP/IP - enables the video server to receive status/data and send com-

mands via TCP/IP

Generic HTTP - enables the video server to receive status/data and send com-

mands via HTTP

Pan Tilt Zoom (PTZ) - for controlling a PTZ device. A PTZ device requires a

driver for its function. Please see page 28 for information on how to connect PTZ

devices. Drivers can be obtained from www.axis.com