Setup Instructions
Connecting the Batteries

The UPS1500EPM ships with the eight batteries installed inside the unit.
Before use, you will need to connect the main power connector inside the
unit:
1.

Remove the Release tabs on the front panel (see FIG. 1) to expose
the screws that secure the Battery Compartment Cover.

2.

Remove the screws beneath the Release tabs (FIG. 3).

3.

Remove the Battery Compartment Cover to access the Battery Com-
partment.

4.

Connect the 4-pin connector from the battery cable harness to the
matching connector inside the unit (FIG. 4).

Connecting the EPM To The UPS

FIG. 5 illustrates connecting the DC Cable on the EPM(s) to the UPS:

EPM - Storage Instructions

For extended storage through moderate climate +5 - +86 °F
(-15 - +30 °C), the batteries should be charged for 12 hours every 6
months by plugging the UPS power cord into the wall receptacle.
Repeat this every 3 months under high temperature +86 to +113 °F
(+30 to +45 °C) environment.

FIG. 3 Remove the screws that secure the Battery Compartment Cover

FIG. 4 Connect the battery cable harness to the matching connector inside the unit

4-pin connector from the

battery wiring harness

4-pin connector power

connector inside the enclosure

FIG. 5 Connect DC Cable