Upnp (ssdp) settings, Mdns settings, Upnp (ssdp) – Samsung CLX-9250ND-XAA User Manual

Page 57: Mdns

Advertising
background image

Network setup_ 57

traps from the system.

-

Authentication Failure Alerts: Check to enable this option. If

you enable this option, the Trap server can get notification for

authentication failure related traps from the system.

-

Cold Start Alerts: Check to enable this option. If this option is

enabled, the Trap server can get notification during hard bootup

(restarting the system by turning the switch off/on).

-

Warm Start Alerts: Check to enable this option. If this option is

enabled, the Trap server can get notification during warm bootup

(restarting the system without turning the switch off /on).

-

Community Name: Enter the community name.

Edit: Select the server you want to edit and press this button.

Delete: Select the server you want to delete and press this button.

SNMP Community

You can see the community status and its permissions. Configure the

settings and press OK to save the settings.
Press Machine Setup > Network Settings > SNMP Settings > SNMP

Community from the display screen.

Add: Press this button to add a new SNMP community.

-

Community Status: Check to enable community.

-

Community Name: Enter the community name.

-

Access Permission: Select the access permission.

Edit: Select the community you want to edit and press this button.

Delete: Select the community you want to delete and press this

button.

UPnP (SSDP) settings

You can set UPnP (SSDP) protocol. Configure the settings and press OK to

save the settings.
Press Machine Setup > Network Settings > UPnP Settings from the

display screen.

You can also use this feature from the SyncThru™ Web Service.

Open the Web browser from your networked computer and type the IP

address of your machine. When SyncThru™ Web Service opens, click

Settings > Network Settings > UPNP (see "UPNP" on page 84).

SSDP: Select whether to enable or disable SSDP (Simple Service

Discovery Protocol).

SSDP TTL: Enter the packet time to live. 4 is set as a default value.

Port Number: Shows the port number.

Friendly Name: Shows the friendly name used by SSDP. Friendly

Name will be same as the Samsung model name (IP address) used by

the SSDP protocol and is shown in Windows network when it detects a

machine.

MDNS Settings

You can set mDNS (Multicast Domain Name System) settings. Configure

the settings and press OK to save the settings.
Press Machine Setup > Network Settings > MDNS Settings from the

display screen.

You can also use this feature from the SyncThru™ Web Service.

Open the Web browser from your networked computer and type the IP

address of your machine. When SyncThru™ Web Service opens, click

Settings > Network Settings > mDNS (see "mDNS" on page 84).

MDNS Enable: Select whether to enable or disable mDNS.

Port Number: Shows the port number used by mDNS.

mDNS Name: Shows the instance name used by the services for

registering via mDNS.

Friendly Name: Shows the friendly name used by mDNS. Friendly

Name will be same as the link address used by the mDNS protocol and

is shown in the Windows network when it detects a machine.

Advertising
This manual is related to the following products: