General information, Hood exhaust, Outside top exhaust (example only) – Samsung ME179KFETSR-AA User Manual

Page 4: Outside back exhaust (example only)

Advertising
background image

4

General information

NOTE: Read these next two pages only if you plan to vent your exhaust to the outside. If you plan to

recirculate the air back into the room, proceed to page 11.

OUTSIDE TOP EXHAUST (EXAMPLE ONLY)

The following chart contains an example of one possible ductwork installation.

DUCT PIECES

EQUIVALENT

LENGTH

x

NUMBER

USED

=

EQUIVALENT

LENGTH

Roof Cap

24 ft.

x

(1)

=

24 ft.

12 Ft. Straight Duct

(6˝ Round)

12 ft.

x

(1)

=

12 ft.

Rectangular-to-

Round Transition

Adaptor*

5 ft.

x

(1)

=

5 ft.

Equivalent lengths of duct pieces are based on actual tests

and reflect requirements for good venting performance with

any vent hood.

Total Length

=

41 ft.

* IMPORTANT: If a rectangular-to-round transition adaptor is used, the bottom corners of the damper will have to be

cut to fit, using the tin snips, in order to allow free movement of the damper.

OUTSIDE BACK EXHAUST (EXAMPLE ONLY)

The following chart contains an example of one possible ductwork installation.

DUCT PIECES

EQUIVALENT

LENGTH

x

NUMBER

USED

=

EQUIVALENT

LENGTH

Wall Cap

40 ft.

x

(1)

=

40 ft.

3 Ft. Straight Duct (3 ¼˝

x 10˝ Rectangular)

3 ft.

x

(1)

=

3 ft.

90 ° Elbow

10 ft.

x

(2)

=

20 ft.

Equivalent lengths of duct pieces are based on actual tests

and reflect requirements for good venting performance with

any vent hood.

Total Length

=

63 ft.

NOTE: For back exhaust, care should be taken to align the exhaust with the space between studs, or the wall should be

prepared at the time it is constructed by leaving enough space between the wall studs to accommodate the exhaust duct.

HOOD EXHAUST