General information, Exhaust connection, Maximum duct length – Samsung ME179KFETSR-AA User Manual

Page 5: Elbows, transitions, wall and roof caps, etc

Advertising
background image

5

General information

Outside ventilation requires a HOOD EXHAUST DUCT.

Read the following carefully.

NOTE: It is important that venting be installed using

the most direct route and with as few elbows as

possible. This ensures clear venting of exhaust and

helps prevent blockages. Also, make sure dampers

swing freely and nothing is blocking the ducts.

Exhaust connection:

The hood exhaust has been designed to mate with a

standard 3 ¼˝ x 10˝ rectangular duct.

If a round duct is required, a rectangular-to-round

transition adaptor must be used. Do not use less

than a 6˝ diameter duct.

Maximum duct length:

For satisfactory air movement, the total duct length of

3 ¼˝ x 10˝ rectangular or 6˝ diameter round duct should

not exceed 140 equivalent feet.

Elbows, transitions, wall and roof

caps, etc.,

present additional resistance to airflow

and are equivalent to a section of straight duct which is

longer than their actual physical size. When calculating

the total duct length, add the equivalent lengths of all

transitions and adaptors plus the length of all straight

duct sections. The chart below shows you how to

calculate total equivalent ductwork length using the

equivalent length in feet of some typical ducts.

DUCT PIECES

EQUIVALENT

LENGTH

x

NUMBER

USED

=

EQUIVALENT

LENGTH

Rectangular-to-Round

Transition Adaptor*

5 ft.

x

( )

=

ft.

Wall Cap

40 ft.

x

( )

=

ft.

90 ° Elbow

10 ft.

x

( )

=

ft.

45 ° Elbow

5 ft.

x

( )

=

ft.

90 ° Elbow

25 ft.

x

( )

=

ft.

45 ° Elbow

5 ft.

x

( )

=

ft.

Roof Cap

24 ft.

x

( )

=

ft.

Straight Duct 6˝ Round or 3 ¼˝

x 10˝ Rectangular

1 ft.

x

( )

=

ft.

Total Ductwork =

ft.

* IMPORTANT: If a rectangular-to-round

transition adaptor is used, the bottom

corners of the damper will have to be cut

to fit, using tin snips, in order to allow free

movement of the damper.

Equivalent lengths of duct pieces

are based on actual tests and reflect

the requirements for good venting

performance with any vent hood.

(Installation)ME179KFETSR_DE68-04129A_AA.indd 5

2012-05-21 �� 9:57:24

Advertising