Trouble shooting, Problem checking and method of pcb, Warning – Samsung WF501ANW-XAA User Manual

Page 17

Advertising
background image

17

Hall Sensor Check

Check Voltage at Pin #4 and #3 of CN3

Tester Check = DC 0V or 1.3V

Check Voltage at Pin #4 and #2 of CN3

Tester Check = DC 0V or 1.3V

Motor Check

Resistance at Pin #1 of #2 of CN8 = 12Ω

Resistance at Pin #2 of #3 of CN8 = 12Ω

Resistance at Pin #3 of #1 of CN8 = 12Ω

Door Lock Check

Check Voltage at Pin #1 of CN6 and Pin #5 of CN1

When Door Lock = AC 120V

Drain Motor Check

Check Voltage at Pin #1 of CN6 and Pin #3 of CN1

When Drain Pump operates = AC 120V

Water Valve Check

Check Voltage at Pin #1 of CN6 and Pin #1,2,7,8,9 of

CN1

When Each Valve operates = AC 120V

AC Power Check

Check Voltage at Pin #1 and #2 of CN6

Check Voltage at Pin #1 CN2 and Pin #2 of RY1

WASH Heater Relay Check

Check Voltage at Pin #1 of CN6 and Pin #2 of RY13

When Heater Relay operates = AC 120V

PROBLEM CHECKING AND METHOD OF PCB

- If you plug in the power cord and turn Power S/W on, memorized data is displayed.

If any data is not displayed, check the followings.

Thermistor Check

Check Voltage at Pin #4 and #5 of CN6

Tester Check = DC 1.6V

If it ready 5V, check if its connector is engaged

properly.

Water Sensor Check

Check Voltage and Frequency at Pin #6 and #5 of CN6

Reset water level = DC1.6V, 26.0KHz

Check Voltage and Frequency at Pin #7 and #5 of CN6

Reset water level = DC1.6V, 26.0KHz

TROUBLE SHOOTING

To avoid risk of electrical shock, personal injury or death; disconnect power to washer

before servicing, unless testing requires power.

WARNING

(Technical information)WF501ANWX-03011B_EN.indd 17

2011-06-24 �� 6:20:25

Advertising