50

Reset time:

When the power supply has automatically shut down, and the short cir-
cuit, over-current and/or over-voltage conditions have ceased to exist,
power will be automatically recycled to restart the power supply within 3
seconds of such return to normal conditions.

No load start:

When the power supply is switched on but with no load connected, the
power supply does not get damaged, and it is still completely safe for
users.

Transient response:

Dynamic load change: ±50% of maximum rating load

Recovery time: 500

µs max.

Reliability:

Mean time between failures (MTBF):100,000 hours minimum

Operating temperature:

0 ~ 50° C

Storage temperature:

-40 ~ 60° C

Operating and storage humidity:10 ~ 95% RH

Operating altitude:

sea level ~ 15,000 ft

Storage altitude:

sea level ~ 50,000 ft

International Standards Compliance

Safety:

UL 1950
CSA 22.2 No. 234
TUV EN 60950

EMI:

FCC Part 15 Subpart J Class B