TROUBLESHOOTING:

CAUSE

SOLUTION

PROBLEM

1. SET POINT DIFFICULT TO SET OR

CANNOT BE REACHED

SUPPLY TEMPS NOT WITHIN
SPECIFIED LIMITS

HOT AND COLD SUPPLIES ARE
REVERSED

CHECK DIFFERENTIAL TEMPERATURE
BETWEEN SUPPLIES AND OUTLET

REINSTALL VALVE WITH SUPPLIES
CONNECTED TO MARKED INLETS

2. DOES NOT MAINTAIN OUTLET

TEMPERATURE OR CHANGES

FLUCUATION IN SUPPLY
PRESSURES

FILTERS BLOCKED WITH DEBRIS

CHECK DIFFERENTIAL TEMPERATURE
BETWEEN SUPPLIES AND OUTLET

CLEAN FILTERS

OVER TIME

3. DISCHARGE TEMPERATURE TOO

HOT OR TOO COLD

VALVE NOT ADJUSTED PROPERLY

READJUST VALVE TEMPERATURE PER
INSTALLATION INSTRUCTIONS

4. NO FLOW FROM VALVE

HOT OR COLD SUPPLY FAILURE
OR SHUTOFFS CLOSED

OPEN SHUTOFFS OR RESTORE HOT
AND COLD SUPPLIES

CHECK FILTERS BLOCKED WITH
DEBRIS

CLEAN FILTERS