Allied Telesis AT-IX5-28GPX User Manual

Page 79

Advertising
background image

IX5-28GPX Installation Guide

79

Note

The User Exec mode is the first level in the command mode
interface. For complete information on the modes and commands,
refer to the Software Reference: AlliedWare Plus Operating System
for IX5-28GPX Switches
.

3. Enter the SHOW STACK command to display the status of the

VCStack feature. Figure 35 is an example of the command.

Figure 35. SHOW STACK Command

4. Review the following items:

ˆ

If the Operational Status is “Stacking Hardware Disabled,” the
VCStack feature is already disabled on the switch and the SFP+
stacking slots may be used with regular SFP or SFP+ transceivers.

ˆ

If the Operational Status is “Standalone Unit,” as shown in Figure
35 on page 79, th
e VCStack feature is active on the unit. You must
disable it by performing the steps in the rest of this procedure
before you can use the SFP+ stacking slots with regular SFP or
SFP+ transceivers. The reason the status says “standalone” is
because the switch considers itself a stack of one switch.

5. Move to the Global Configuration mode by entering the ENABLE and

CONFIGURE TERMINAL commands, as shown in Figure 36.

Figure 36. Moving to the Global Configuration Mode

6. To. disable the VCStack feature on the switch, enter the NO STACK

ENABLE command, which has this format:

no stack

id

enable

awplus> show stack
Virtual Chassis Stacking summary information

ID

Pending ID

MAC address

Priority

Status

Role

1

-

0015:774f:ed30

128

Ready

Active Master

Operational Status

Standalone Unit

Stack MAC address

0015:774f:ed30

awplus(config)#

awplus> enable
awplus# configure terminal
Enter configuration commands, one per line. End with CNTL/Z
awplus(config)#